Symptom
Cradle will not drive in or out. Cradle will not drive in or out
Error message
Error: 260115184 Cradle drive fatal fault occur Cradle drive fatal fault occur FaultCode : Not Assigned ExtFault : Not Assigned Tue Mar 8 05:52:44 2011 Error: 260115184 Host: tgp Process: tgp_subsys File: mtcb_cmc_action.c Line: 526 Tue Mar 8 05:52:44 2011 Host : Table Sub-System Ermes # : 260115184 Exception Class : Secondary Severity : Pri/Soft File : mtcb_cmc_action.c Line# : 526 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle drive fatal fault occur FaultCode : Velocity feedback(VelFB) over speed ExtFault : Variable Resolver Overspeed. |VelFB| > max(VelLmtxx)*1.5 Error: 260115183 Cradle drive fault occur see long Description Thu Mar 26 17:08:51 2009 Host : Table Sub-System Ermes # : 260115183 Exception Class : Secondary Severity : Pri/Soft File : mtcb_cmc_action.c Line# : 494 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle drive fault occur FaultCode : Resolver Fault ExtFault : Not Assigned or FaultCode : Velocity feedback(VelFB) over speed ExtFault : Variable Resolver Overspeed. |VelFB| > max(VelLmtxx)*1.5 Error: 260115191 Cradle position is out of tolerance See long description for full error Thu Sep 1 09
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2342729-3 Elevation or Cradle Drive Amplifier used on the 5.X table - same driver amp is used for both See LD for additional part information Part #: 2342729-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: H-POWER TABLE SERVO DRIVE, EMC EDITION 2 COMPLIANT FRU: Yes Status: Orderable Comments: **Please consider ordering the used part when it is appropriate for your customer. It will save you substantial money.** Part added per DST-HP60 16 slice RSPL. 040906 MS13452.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.