GE Healthcare · CTLightSpeed183156

LightSpeed 4.X - GRE

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183156 Unable to PREP generator. Sun Sep 5 11:10:28 2004 Error: 183156 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 404 Function: XRAY GENERATION : Tube Rotor Control Scan: 4167/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 11:10:29:170 Log Series: 43 Unable to PREP generator.

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2117848-7 20 meter DAS Fiber Optic Cable (short) used on HSA, CTi and 1.x QXi. See LD for detail Part #: 2117848-7 Part Type: GP CONSUMABLES Part Weight: 25.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: 20000 +/- 150 FIBER OPTIC CABLE FRU: Yes Status: Orderable Parts Offered as: Current: 2117848-7 Harvested: Not Available Exchange: Not Available Comments: FLS - 20000 +/- 150 FIBER OPTIC CABLE. ADDED PER PCN 220581. MS20544 ON 1/17/03
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.