GE Healthcare · CTLightSpeedVCT290009016290009010290009007
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanning fails with recon errors
Error message
Error: 290009016 Recon is going to SHUTDOWN mode due to XXXXXX. See Long Description for Error variation Tue Jul 12 14:31:49 2005 290009016 4 darc recon_control recon_control_cb.cxx 464 Recon is going to SHUTDOWN mode due to no IG can be used to perform reconstruction. Mon Aug 31 23:13:32 2009 Error: 290009016 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 6029 Recon is going to SHUTDOWN mode due to maximum number of consecutive suspends reached. Error: 290009010 Image suspended due to: image installed with status -1. See long description for full error Fri Sep 30 15:00:17 2005 Error: 290009010 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 4129 Function: Image Generation : SBC Processing Job Type: RECON_JOB_PROS_AXIAL_RECON Scan: 613/2/6 Image: 613/2/22 Image suspended due to: image installed with status -1. Number of retry so far: 2. IG node: 0. Error: 290009007 Timeout waiting for image available. Number of retry so far: 1. IG node: 0. Sun May 14 14:05:42 2006 Error: 290009007 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 5208 Function: Image Generation : SBC Processing Job Type: RECON_JOB_PROS_HELICAL_RECON Scan: 378/2
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required