GE Healthcare · CTHiSpeed102081017910180101911689610174
Unable to attach and label MOD disks
Symptom
Unable to attach and label MOD disks
Error message
Error: 10208 Archive Job Processing Error see long description Tue Apr 22 15:58:05 2008 Error: 10208 Host: rtct Process: arsjob File: arsjob.c Line: 721 Archive Job Processing Error Error: 10179 Internal error in label job see long description Tue Apr 22 15:58:05 2008 Error: 10179 Host: rtct Process: arsjob File: ArchiveDevice.c Line: 4078 Internal error in label job Error: 10180 Resetting ARS HITACHIOD172-11 See long description for a sample error message. Wed Jul 7 13:07:48 2010 Error: 10180 Host: MRHCT1 Process: arsjob File: ArchiveDevice.c Line: 4615 Resetting ARS HITACHIOD172-11 - $Id: @(#)ArchiveDevice.oN32 builder Mon Dec 13 14:43:31 JST 2004 /view/np pls v10 $ Error: 10191 Failed save exam. Mon Nov 27 03:45:02 2006 Error: 10191 Host: emc1 Process: arserver File: arscommand.c Line: 2304 Failed save exam. Paused 16896 Error: 10174 Internal error in ArchiveDevice See the long description for the full error code Sun Jun 19 21:46:55 2005 Error: 10174 Host: ct01 Process: arsjob File: ArchiveDevice.c Line: 5047 Internal error in ArchiveDevice
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2245963 Sony MOD SMO-F551 drive used on CTE and HiSpeed Xi scanners See LD for more info 2245963 Sony MOD drive used on CTE and HiSpeed Xi scanners Part #: 2245963 Part Type: GP REPAIRABLES Part Weight: 0.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: MISC ELECTRONIC COMPONENT OPTICAL DI FRU: Yes Status: Orderable Comments: FLS - MOD DRIVE (SONY) U/O YMS-CTE SYSTEM HISPEEDS MS08992 1/21/00 NO LONGER REPAIRABLE, CHANGE TO 2245963 WHEN STOCK OF T3697ET IS DEPLETED. 5-02, A. MASCH 9/3/02- C2R IN PROCESS PER OSAMU KANAYA. MS12464 REPAIR FLAG TURNED NOV 2002 GELS - THE PART NUMBER OF MOD IS CHANGED FROM 2194318 TO 2245963 (SONY SMO-F551). AT THE SAME TIME, SCSI CHAIN CABLE ASSY IS CHANGED FROM 2155895 TO 2155895-2 BECAUSE SCSI CONNECTOR OF NEW MOD ,MOD DRIVE (SONY)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required