GE Healthcare · CTBrightSpeedVCT26011201513070
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.
Error message
Error: 260112015 The Gantry Touch Sensor FAULT ( error text varies ) See long description for error examples Error text varies. Tue Sep 4 10:28:17 2007 Error: 260112015 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9075 Tue Sep 4 10:27:02 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 9075 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 6891/2/0 The Gantry Touch Sensor FAULT. Gantry Sensors: BACK Touch Sensor Error(s). Gantry Controls are running in FAULT MODE. Operator's Console Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry Sat Nov 17 00:07:55 2007 Error: 260112015 Host: tgp Process: tgp subsys File: uif table tilt mgr gt.c Line: 13070 Sat Nov 17 00:07:54 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif table tilt mgr gt.c Line# : 13070 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 The Gantry Touch Sensor FAULT. Gantry Sensors: FORWARD Touch Sensor Error(s). Gantry Controls are running in FAULT MO
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required