LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118289 (60-0329) Wrong HV capacitance measured. See Long Description for complete error. Wed Sep 19 13:17:47 2007 Error: 260118289 Host: orp Process: orp_subsys File: gen_exec.c Line: 2376 Running diagnostic: kV and mA Test: Xray Functional Test Wed Sep 19 13:17:46 2007 Host : Jedi Ermes # : 260118289 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2376 Function : No System Function Reported Scan Type : Static Scan: 50327/1/1 (60-0329) Wrong HV capacitance measured. JEDI must be reset after KV Diags are performed.

Error: 260100117 Timeout on Exposure Complete Data containing the Generator Xray Scan Information (Avg mA). See long description for sample error. Tue Jun 22 09:46:30 2010 Error: 260100117 Host: tgp Process: tgp subsys File: scTrigSeqActions.c Line: 1737 Exception Class : Abort Severity : Secondary Function : XRAY GENERATION : Final Exposure Command Scan Type : Axial Scan: 10697/2/4 Timeout on Exposure Complete Data containing the Generator Xray Scan Information (Avg mA). HW Error: Possible hardware problem. Timeout is: 650 mS.

Error: 260100032 Timeout on Exposure Command reset to x-ray off! See LD for complete error Wed Mar 15 09:25:29 20

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required