GE Healthcare · CTLightSpeedVCT26010100824454026010102250060260101071260101014
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scan aborts WITH Communications with the CCB sub-system has not been established. Scan aborts WITH Communications with the CCB sub-system has not been established
Error message
Error: 260101008 The ORP failed to connect with the CCB sub-system in the allotted time. Check to see if subsystem is alive.Timeout value: 4000ms error 260101008 The ORP failed to connect with the CCB sub-system in the allotted time. Check to see if subsystem is alive.Timeout value: 4000ms Open LD to see error example Error: 260101008 The ORP failed to connect with the CCB sub-system in the allotted time. Check to see if subsystem is alive. Timeout value: 40000mS This was followed by Error: 244540 Immediate Request cannot be honored since the firmware is in the DOWN state. Error: 260101022 Communications between the CCB sub-system and ORP have been lost. See LD for more details Mon Apr 10 07:20:42 2006 Error: 260101022 Host: orp Process: orp subsys File: rcib init state.c Line: 267 Mon Apr 10 07:20:41 2006 Host : On-Board Rotating Processor Ermes # : 260101022 Exception Class : Abort Severity : Primary File : rcib init state.c Line# : 267 Function : No System Function Reported Scan Type : None/Unknown Scan: 50060/6/0 Communications between the CCB sub-system and ORP have been lost. Attempting to establish communications. Error: 260101071 The CCB has reset unexpectedly. See LD for
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required