GE Healthcare · CTLightSpeedVCT
Customer does not hear or feel the top gantry fans running.
Symptom
Customer does not hear or feel the top gantry fans running.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5340738 (replaces 2359114) HPOWER GANTRY FAN AND HARNESS used on 5.x gantry See Long Description for details This fan for BrightSpeed, HP100, HP60 and RT Systems. Part #: 5340738 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY FAN AND HARNESS FRU: Yes Status: Orderable Comments: Per ECR 2091297, 212008898, 10/26/09. Part #: 2359114 <-- All GPRS stock is gone and this part is now obsolete Part Type: GP CONSUMABLES Part Weight: 8.82 LBR Repairable: No Returnable: No Hazardous Material: N Description: HPOWER GANTRY FAN AND HARNESS FRU: Yes Status: Orderable Comments: FLS - HPOWER GANTRY FAN AND HARNESS.ADDED PER THE HPOWER RSPL. EXPECTED M3 FOR THIS PROGRAM: FW19, 2003. MS20544 2/28/03.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required