GE Healthcare · CTLightSpeed2300000675000416800015000
LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2
Symptom
"Scan hardware Stopped Scan" with Taxi data violation errors. "Scan hardware Stopped Scan" with Taxi data violation errors
Error message
Error: 230000067 Unexpected event occurred during scan data transfer See the long description for the full error code Sat Apr 17 20:34:13 2004 Error: 230000067 Host: darc Process: dataacq File: dip_thread.cxx Line: 390 Running diagnostic: Scan Data Path Functional Function: Data Acquisition : Scan Data Acquisition Scan Type: Xray-on Static Scan: 50004/4/1 Scan Seq Id: 168000 Unexpected event occurred during scan data transfer. Event bit: 7 Count: 1 Description: Global bus error: read attempted from the Test Data FIFO Scan aborted. OR Tue Mar 6 07:13:50 2007 Error: 230000067 Host: darc Process: dataacq File: vdip.cxx Line: 817 Function: Data Acquisition : Scan Data Acquisition Scan Type: Cine Scan: 50004/6/1 Scan Seq Id: 15000 Unexpected event occurred during scan data transfer. Event bit: 22 Count: 1 Description: DMA interrupt was not cleared Scan aborted.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2 This is HP CPU host running LINUX with Pegasus IG. 308L.8_H3.3M4 ~ 4 or 8 slice MDAS. ~ Could be an Ultra, Plus or QXi system. Must run swokinstall -p to verify. ~ See Long description for details . LightSpeed 3.X MDAS4 Gantry and GOC2 Gantry - 2281177-2, DAS - 2272768, Console – 2341104-2, Table - 2276776, PDU - 2269902 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2259530 H3 PMC DIP See LD for more info 2259530 H3 PMC DIP Part #: 2259530 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: H3 PMC DIP FRU: Yes Status: Orderable Comments: FLS - H3 DIP BOARD. USED ON WARP3. SUPPLIER IS SCI. SEE FE ASSIST. COLLECTION OF DEFECTIVES START7/23/01 MS5277 4/25/02- UNDER REPAIR DEVELOPMENT PER P REILLY. MS12464 5/7/03 - CHANGED BACK TO R0010BY P. REILLY MS12575 GELS - ***************FE ASSIST***************************** OLCE / PDB 01/11/28 ---H1 O2LESS --- QUARTZ FREQ. 44 MHZ : REF FRU : # 2216666,PCB H3 DIP
- Area
- CT
Full cause & step-by-step resolution