GE Healthcare · CT244596
Lightspeed 1.X - Octane
Symptom
Gantry reset failed. Version Mismatch was Detected between a Firmware Controller and the SRU Disk. Gantry reset failed. Version Mismatch was Detected between a Firmware Controller and the SRU Disk
Error message
Error: 244596 A Version Mismatch was Detected between a Firmware Controller and the SRU Disk. Firmware File: /usr/g/fw/alms/ETCScan.bin See LD Error: 244596 A Version Mismatch was Detected between a Firmware Controller and the SRU Disk. Firmware File: /usr/g/fw/alms/ETCScan.bin Tue May 16 07:07:51 2006 Error: 244596 Host: ct02_sbc Process: fwmgr File: HwSetUp.c Line: 1000 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 A Version Mismatch was Detected between a Firmware Controller and the SRU Disk. Firmware File: /usr/g/fw/alms/ETCScan.bin
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2197229-5 ETHERNET SWITCH, 8 PORT used in 1X/2X/3X/4X GOC1/GOC2 See long description for more details Part #: 2197229-5 Part Type: GP CONSUMABLES Part Weight: 1.94 LBR Repairable: No Returnable: No Hazardous Material: N Description: ETHERNET SWITCH, 8 PORT FRU: Yes Status: Orderable Comments: FLS - ETHERNET SWITCH, 8 PORT. ADDEDPER PCN 220607. REPLACES P/N 2197229-3 AND -4. USE EXISTINGSTOCK FIRST. MS20544, 8/15/02.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.