GE Healthcare · CTLightSpeedVCT290009014126913125375125196

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Images fail to display and get suspended in the recon queue

Error message

Error: 290009014 Recon Statistics since XXX - # failed dicom, # failed installation, # retried, # suspended, OR # IG reset (s) See Long Description EXAMPLE Below: Mon Mar 29 08:23:16 2010 Error: 290009014 Host: darc Process: recon_control File: ImageSetRequestList.cxx Line: 1832 Recon Statistics since Fri Mar 19 06:36:55 2010 : 0 requested 126913 sent to IG * 125375 completed by IG * 0 failed in IG * 125196 dicom ok * 115 failed dicom * 125196 installed ok 79 failed installation * 121 retried 73 suspended 0 deleted from queue 2 IG reset * includes retries

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
10MW06.5 Titan for VCT (MUST HAVE SP1 or Higher) Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release) 10MW06.5 Titan for VCT Delivered via new install or FMI 25425 Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required