Discovery 530c Modality worklist query fails with error message "Could not perform the operation" displayed in…
Discovery NM 530c/570c
Symptom
Discovery 530c Modality worklist query fails with error message "Could not perform the operation" displayed in a pop-up window. \ Discovery 530c Modality worklist query fails with error message "Could not perform the operation" displayed in a pop-up window. Key Error : java.lang.ArrayIndexOutOfBoundsException: 0 ERROR UN CAUGHT ERROR (Error 10502) Uncaught exception Captured Errors : Messages Chain: DEVELOPMENT ERROR MESSAGE=Uncaught exception: java.lang.ArrayIndexOutOfBoundsException USER ERROR MESSAGE=Could not perform the operation USER FIX=1. Try again 2. Restart the Application CODE=(ERROR UN CAUGHT ERROR,10502,ERROR) SOURCE=com.ge.med.fi.tacq.dm.browser.PatientsViewerFrame$2 9@39826 TIME CREATED=Thu Oct 15 11:05:05 EDT 2009 Caused by:Exception: java.lang.ArrayIndexOutOfBoundsException: 011:05:05 WARNING = Warning in PEFApp in Class MWLUtility.java:773 -MWLUtility::fillRequestAttributesSequence. Queried empty SPS ID from MWL. This is unexpected!!
Error message
ERROR_UN_CAUGHT_ERROR,10502 Uncaught exception ERROR_UN_CAUGHT_ERROR:.:Could not perform the operation:.:1. Try again 2. Restart the Application:.: Uncaught exception: Caused by:Uncaught exception: java.lang.NumberFormatException For input string: "10@;9 4127=10" :.:Trace:java.lang.NumberFormatException View error in [email protected]
Applies to
- Models
- Discovery, Infinia
- Product
- Discovery NM 530c/570c Discovery NM 530c/570c (CZT) DSV NM 530c DSV NM 570c
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.