Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT2005015332006000252000018212451831795488000

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors

Error message

ERROR: 200501533 Event Router process with status: Timed out while attempting to receive a message.. See LD for variations of this error. ERROR: 200501533 Process Timed out while attempting to receive a message. Wed Feb 28 17:51:14 2007 Error: 200501533 Host: ct99 Process: scanRx File: uifIpcCommonFunctions.c Line: 2270 Function: No system function reported Service uif_scan_rx failed to receive message with event code 3141 from Event Router process with status: Timed out while attempting to receive a message. Below is another example of a different process that timed out: Fri Dec 30 10:03:25 2005 200501533 4 ctls16 reconMgmt uifIpcCommonFunctions.c 2269 Function: No system function reported Service uif_recon_mgmt failed to receive message with event code 3123 from Event Router process with status: Timed out while attempting to receive a message. Also saw these in the gesyslog: Fri Dec 30 10:02:48 2005 200600025 2 ctls16 retroRecon UIRxToRetroRequest.cxx 302 Could not send request to Qmanager, EV_QUEUE_SYNOPSIS, status 200001821 From /var/log/messages in the darc: 30 10:01:07 darc kernel: Uhhuh. NMI received for unknown reason 31. Dec 30 10:01:07 darc kernel: Dazed and confused, but

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues