GE Healthcare · X-ray R&FRevolution
Revolution XRD-2X (Lightning) exposure stops intermittently Spit Max error Customer call service for some time…
Revolution XRD-2X (Lightning) exposure stops intermittently Spit Max error
Symptom
Revolution XRD-2X (Lightning) exposure stops intermittently Spit Max error Customer call service for some time the system can't do any exposure when system report " Tank Thermal sensor to high", after reboot, the lighting DR exposure stops intermittently the error is " generator/tube spits"
Error message
Spit Max error, Generator temperature too high, kV max detected, ILR max current detected China support Lindewei: " Generator error 60-0310: kV max detected" KV reach 160KVP during exposure was detected. The error also cause by KV control board defect or HV tank arcing during exposure. " Generator error 60-0313: ILR max current detected". hardware detection of maximum current in serial resonant circuit. It should cause by tube spit, HV tank failed in high load, KV control board defect. " Generator error 60-0316 Spit Max error"kV control has detected the number of tube spits limit from system error logs ( china support Lindewei) " Generator error 60-0310; (3): kV max detected" It means KV reach 160KVP during exposure was detected. The error also cause by KV control board defect or HV tank arcing during exposure. " Generator error 60-0313; (3): ILR max current detected". This is a hardware detection of maximum current in serial resonant circuit. It should cause by tube spit, HV tank failed in high load, KV control board defect. " Generator error 60-0316; (3): Spit Max error". It means kV control has detected the number of tube spits during exposure has reached the limit. It also caus
Applies to
- Models
- Revolution
- Product
- Revolution XRd2X
- Software
- Revolution XR/d 2X Platform (Lightning) – M4
- Component
- Wallstand (Revolution XR/d 2X) Wallstand (Revolution XR/d 2X) HV TANK, P/N: 2214527 1, HV TANK, P/N: 2214527PROGRAMMED 2, KV CTRL P6.22BF2, P/N:2407577 changed to "5136161-4" JEDI Generator This generator is used on Proteus and Precision 500D systems.
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…
- Revolution XRd2X Worklist query on "All Systems in this Modality" does not retrieve anything after FMI 10791A is completed due to the default query set to DX.
- Revolution XR/d error 4280 when trying to make exposure to table or wallstand detector
- Revolution XRd 2X The HP Workstation reboots itself.
- Def8000, Def5000, Revolution XRd and XRD2X Latent lead marker image burned into the detector.