GE Healthcare · CTBrightSpeed260101008
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Hardware reset fails with ORP to (CCB, DCB or Jedi)communication errors. Hardware reset fails with ORP to CCB communication errors.
Error message
Error: 260101008 The ORP failed to connect with the DCB sub-system in the allotted time. See LD Wed Jul 12 06:02:29 2006 Error: 260101008 Host: orp Process: orp_subsys File: rcib_node_init.c Line: 110 Wed Jul 12 06:02:30 2006 Host : On-Board Rotating Processor Ermes # : 260101008 Exception Class : Soft Severity : Pri/Soft File : rcib_node_init.c Line# : 110 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 The ORP failed to connect with the DCB sub-system in the allotted time. Check to see if subsystem is alive. Timeout value: 40000mS
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2371626-4 GDAS / MDAS 16 Slice CENTER Backplane See long description for details Part #: 2371626-4 Part Type: GP CONSUMABLES Part Weight: 1.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: GDAS-MDAS 16 Slice CENTER BP-Chassis Asm FRU: Yes Status: Orderable Comments: This part is replacement for 2371626, -2, & -3. ms13452 050605
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required