Pular para o conteúdo principal
GE Healthcare · CTLightSpeedBrightSpeed260118168186218

LightSpeed 5.X (60kW)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118168 (40-0105) Rotation Phases unbalanced See LD for error explanation Code 40 Error code: 40-0105H Message/explanation: Rotation Phases unbalanced The amplitude difference of the current between main and auxiliary is too large. Potential cause: 1. Tube stator winding problem 2. Incorrect wiring (one wire open) 3. Phase shift capacitors inverted or wrong value or not connected 4. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance. If not OK, replace tube. Check wiring from rotation board to tube. Check that phase shift capacitors are correctly connected Check that phase shift capacitors are not in short-circuit Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board Tue May 9 09:26:56 2006 Error: 186218 Host: IRIS Process: tgp_out File: tgp_in_input.c Line: 335 XG Error phase is 3 code is 40. detail error code : 40 - 0105H Rotation error : Rotation Phases unbalanced

Applies to

Models
LightSpeed, BrightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2368445 - P2053RJ HV CABLE HEMIT LONG - used on HP Jedi See Long Descriptions for details. 2368445 - P2053RJ HV CABLE HEMIT LONG - used on HP Jedi Part #: 2368445 Part Type: GP CONSUMABLES Part Weight: 0.99 KGM Repairable: No Returnable: No Hazardous Material: N Description: P2053RJ HVCABLE HEMIT LONG FRU: Yes Status: Orderable Comments: FLS - P2053RJ HVCABLE HEMIT LONG USED ON: H-POWER60 ADDED PER HP-60 RSPL MS13452 031114 RISK: COSMETIC FREQUENCY: LOW IM05 REQUESTED PDR REQUSTED
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues