Pular para o conteúdo principal
GE Healthcare · CTLightSpeed

LightSpeed 4.X - GRE

Symptom

LAN watchdog Errors

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-296317P3 XENTEK POWER SUPPLY See Long Description for more information including stc and ETC power supply locations Part #: 46-296317P3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: POWER SUPPLY FRU: Yes Status: Orderable Exchange: Not Available Comments: FLS - XENTEK POWER SUPPLY U/O GANTRY & TABLE CTI AND GENESIS AND HORIZON USE P3'S ON CTI ONLY 10/31/96 MS08992 GVR ---------------------------------------------------------- 46-296317P3 REPLACED T3202GT /46-296317P2 PER PCN 189892. MS4636 12/2/96 ---------------------------------------------------------- ALSO USED ON QXI LIGHTSPEED TO BRASIL: IF NO STOCK, CHANGEORDER TO T3202JR. COLLECTION OF DEFECTIVES START7/23/01 MS5277 TAIYO YUDEN P/N 8230 +5VDC, +15VDC, -15VDC, +24VDC,IN 120VAC, 3.6A 50/60HZ MS5900 WAS T3202JR FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PART IF AVAILABLE. IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues