Intermittent helical, axial or scout scan error.
Symptom
Intermittent helical, axial or scout scan error.
Error message
Error: 188415 Continuous Bad Raw detected and Scan is going to aborted. Check status LED on DASIFN See Long Description for Full Error. Tue Aug 16 17:28:41 2005 Error: 188415 IRIS RawStore NdbAccess.c 299 DASIFN Error: Continuous Bad Raw detected and Scan is going to aborted. Check status LED on DASIFN Error: 188800 Error occured in check if available, rawkey Error: 188800 Host: HISPEED Process: RawLoad File: API.c Line: 713 Error occured in check if available, rawkey Error: 188411 [libcall] ioctl(NDB) failed. Bad file number See Long Description for a sample error message. Fri Jun 1 08:15:49 2007 Error: 188411 Host: huzxi Process: RawStore File: NdbAccess.c Line: 262 [libcall] ioctl(NDB) failed. Bad file number
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2245481 Slip Ring (HSDCD Platter) for H2 (125 Mbaud) and YMS Xi gantry's See Long Description for details 2245481 Slip Ring (HSDCD Platter) for H2 Gantry (125 Mbaud) Part #: 2245481 Part Type: GP CONSUMABLES Part Weight: -2061799.38 LBR Repairable: No Returnable: No Hazardous Material: N Description: SLIPRING, HSDCD PLATTER FRU: Yes Status: Orderable Comments: FLS - PLATTER SLIPRING ONLY FOR HINO PROSPEED AND H2 125Mbaud
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.