GE Healthcare · CTLightSpeed26010004226010002750271
LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry.
Symptom
Can't perform Scout Scan. Can't perform Scout Scan Please go to the error concept and check all that apply The customer may see Scanner Hardware Stopped Scan message in the operator console area 1 Use the following script and search the message log at time of Scout failure to get the correct errors. [insite@erct ~]$ /usr/g/insite/bin/viewlog 2 Type those errors in the psdb search box separate by spaces 3 Go to the error concept and check the appropriate errors
Error message
Error: 260100042 Cradle was NOT ready See the long description for the full error code Tue May 17 16:02:03 2005 Error: 260100042 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 70 Tue May 17 16:02:02 2005 Host : Table Gantry Processor Ermes # : 260100042 Exception Class : Soft Severity : Sec/Soft File : scHdwRdy.c Line# : 70 Function : No System Function Reported Scan Type : Scout Scan: 106/1/1 Cradle was NOT ready Error: 260100027 Hardware Timeout. OP/HW Error: Possible operator or hardware problem. See Long Description for a full sample error. Fri Oct 3 07:24:37 2008 Error: 260100027 Host: tgp Process: tgp subsys File: scStartPbLogic.c Line: 354 Fri Oct 3 07:24:37 2008 Host : Table Gantry Processor Ermes # : 260100027 Exception Class : Pause Severity : Primary File : scStartPbLogic.c Line# : 354 Function : No System Function Reported Scan Type : Static Scan: 50271/9/1 Hardware Timeout. OP/HW Error: Possible operator or hardware problem. A list of hardware that is not ready follows:
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2275752 SCIM collector - english. See long description for details. Part #: 2275752 Part Type: GP CONSUMABLES Part Weight: -82269.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: SCIM COLLECTOR - ENGLISH FRU: Yes Status: Orderable Comments: FLS - SCIM COLLECTOR ENGLISH MS26561 DSM SEE FE ASSIST NOTES: ***** A NEW SCIM WILL NOT FIX:(1) INTERCOM SOUND QUALITY: THERE WILL BE AN FMI TO FIX INTERCOM OUT WK 30, (2) STICKING KEYS: TRIM TEMPLATE TO FREE KEYS, DO NOT DISCOUNT - PER SHAKUN SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL***** KIT# B7800KE INCLUDES THIS PART VC = ADVANCED INPUT DEVICES COEUR D'ALENE, ID FLS - ***A NEW SCIM WILL NOT FIX: 1) INTERCOM SOUND QUALITY - THERE WILL BE A FMI TO FIX INTERCOM OUT WK30, 2) STICKING KEYS:TRIM TEMPLATETO FREE KEYS YOU MUST REVIEW TROUBLE SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL*** FE ASSIST: 6/27/02
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required