GE Healthcare · CTDiscoveryVCT200002352230008076260005510
Scanner shutdown on its own to the system halted screen.
Symptom
Scanner shutdown on its own to the system halted screen. Scanner shutdown on its own to the system halted screen
Error message
Error: 200002352 A HOST_SHUTDOWN was initiatied by the unexpected termination of recon_control. Fri Aug 22 15:05:09 2008 Error: 200002352 Host: npct Process: cupMonitor File: ssProcStop.c Line: 766 A HOST_SHUTDOWN was initiatied by the unexpected termination of recon_control. Error: 230008076 An inconsistency has been detected in the Scan File Manager shared memory See Long Discription for Details Wed Aug 4 07:25:07 2010 Error: 230008076 Host: ct04 Process: scanfilemgr File: sfm_shared_utils.c Line: 1722 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 0/0/0 An inconsistency has been detected in the Scan File Manager shared memory. Inconsistencies detected: 1 Requested from: line #5987 of sfm_sharing.c Information appended to: /usr/g/service/log/scanfilemgr.sfm_shared.dump A reboot is recommended. Error: 260005510 Task 'startProcHost' terminated prematurely See Long Discription for Details Wed Aug 4 07:25:07 2010 Error: 260005510 Host: ct04 Process: startProcHost File: startProcHost.cxx Line: 94 Task 'startProcHost' terminated prematurely
Applies to
- Models
- Discovery, VCT
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required