GE Healthcare · CTHiSpeed
CT/e Dual, CT ProSpeed AII/FII Irix or Linux
Symptom
How to remove Class C and Class M software
Applies to
- Models
- HiSpeed
- Product
- CT/e Dual, CT ProSpeed AII/FII Irix or Linux HiSpeed CT/e Dual CT Scanner System see long Description for sales information Product Name: CT/e Dual CT Scanner System Irix A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) N/A Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- V/R 3.30 For CT/Be-2 (HiSpeed Dual, ProSpeed FII) See Long Description for details V/R 3.30 For CT/Be-2 (HiSpeed Dual, ProSpeed FII) APPLIES TO: HiSpeed Dual, ProSpeed FII with HP xw8400 computer, OS CTT6.2.9, Application software 3.30 (3.10 + Patch 3.30). New version software is used on forward production of CT/Be-2 (HiSpeed Dual and Japan Small OC ProSpeed FII) with Hp xw8400 host computer. The software can not be used on IB system currently. FEATURES OF V/R 3.30: V/R 3.30 software is used on forward production of CT/Be-2 (HiSpeed Dual and Japan Small OC) with Hp xw8400 host computer phase in (FW47’07). V/R 3.30 software cannot be used on IB system currently. Calibration/Alignment Authorized Access Function In order to guarantee Image Quality on CT scanner, V/R 3.30 restricts access to some calibration & alignment tools. The system needs a password for 48-hour valid access or a license for permanent valid access. Only GE FE or GE authorized person can access Cal/Alignment functions. A License can be used to get a permanent authority for access-free systems (Sites defined by local Service businesses). See GEHW-SN110705A for details of this feature. DVD Interchange Software Upgraded from V/R4 to V/R6.1, installation procedure is same with the previous. INSITE SOFTWARE (No change, for reference) No change for InSite software. This section is reference information. Software V/R 3.30 should work with Insite Class M software V/R 3.52 (P/N 5150686, TAB 263). Please select Product Line ‘HWCT-E’, Model Type ‘CTELX’ while Checking Out Insite. CT/e Model type: CTELX for Checkout (OLC) IIP3.0.2 or later. PSI code of CT/Be2 keeps same as original one: CSEB04.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required