GE Healthcare · CTLightSpeedVCT17860160956150002452261084000245031
LightSpeed 1.X - GRE
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 178601 Timed out waiting for CF query response See Long Description Mon Nov 23 12:59:34 2009 Error: 178601 Host: ls01 Process: fwmgr File: CF.c Line: 1910 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Timed out waiting for CF query response. Msg code sent to fw: 60956 Response message code: 7407 FW mail box: 10 Response message descriptor: 1 (See process.timers for mapping message descriptor to UUID.) Timeout: 15000 Error: 245226 Scanmgr requested hardware reset. Scanning hardware might be down, or the communication with the firmware might have failed. See LD for complete error Sun Sep 10 05:29:21 2006 Error: 245226 Host: cpro Process: scanmgr File: scanmgr_lib.cxx Line: 1450 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 1084000 Scanmgr requested hardware reset. Scanning hardware might be down, or the communication with the firmware might have failed. Error: 245031 Timeout: Sending Abort Xrays to the Firmware See long description Wed Jun 2 10:01:46 2010 Error: 245031 Host: gect01dan Process: scanmgr File: firmware_if.cxx Line: 955 Function: System Communications : Control Network Scan Type: Heli
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required