GE Healthcare · CTHiSpeed1831581841862152913018318018303

Scanner Hardware Stopped Scan.

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183158 HVDC Bus voltage not sensed in 2 seconds See LD for complete error Wed Sep 20 11:01:10 2006 Error: 183158 Suite: SMCT Host: OBC Process: Generator File: gen_rotor.c 1.40 Method: No Method Function: SYSTEM MONITORING : 550V Monitor Scan: 0/0/1 Type: Static Line: 530 Exception Level: Pri/Most Severe Time: 11:01:10:450 Log Series: 25 HVDC Bus voltage not sensed in 2 seconds. Pilot relays on I/O board closed, pilot relay in PDU energized.

Error: 184186 mains undervoltage See long description for full error code and error explanation Error: 184186 Suite: RP04 Host: STC Process: Scan Control File: scMainsMonitor.c 1.10 Method: No Method Line: 210 Function: SYSTEM MONITORING : Mains Undervoltage Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time:07:29:19:290 Log Series: 27 SRU indicates mains low. EXPLANATION OF ERROR 184186 The manuals below can be found on CDL or the Way2cool Cdrom 2152913-200 under CT/i and Hispeed ( Family Wide ) Refer to Direction 46-018318 Mains Undervoltage for the monitor part. Refer to direction 46-018303 PDU_TRANSFORMER_FUSE_PANEL. The Mains Undervoltage monitor the voltage at PDU fuses A5F10, F11, F12. If this voltage is low, or if a p

Applies to

Models
HiSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-296221P15 80A 600V Fuse See Long Description for details Part #: 46-296221P15 Part Type: GP CONSUMABLES Part Weight: 0.13 LBR Repairable: No Returnable: No Hazardous Material: N Description: BUSSMANN KBC80 FRU: Yes Status: Orderable Comments: FLS - CLASS 1 FRU. PDV BUSSMANN KBC80 80A, 600V THERE ARE 3 OF THESE FUSES IN FUSE KIT 2218570 - MS4751 8/01 PRICE CHANGE PER BRIAN NAGLE 4/98 FLS - FE ASSIST: IN ORDER TO INCREAS INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCRESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE U PART WHEN AVAILABLE. IF NO U USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
Area
CT