Customer can not scan with DAS temperature errors.

Symptom

Customer can not scan with DAS temperature errors. Customer can not scan with DAS temperature errors

Error message

Error: 260132754 Digital Interface Board(s) Detected An Invalid Trim Table on a Digital Module See Long Description for complete error Error: 260132754 Digital Interface Board(s) Detected An Invalid Trim Table on a Digital Module DIFB : 15 A/D Board: 32 Errors in gesys.log, when the problem occurs: Tue May 18 13:22:06 2010 Error: 260101023 Host: orp Process: orp_subsys File: rcib_erlog.c Line: 463 Running: System Reset Tue May 18 13:22:06 2010 Host : Das Ermes # : 260101023 Exception Class : Abort Severity : Primary File : rcib_erlog.c Line# : 463 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 The DCB has notified the system of an error condition which prevents scanning. See log for further information:^C Error message code: 260132755 Notification level: 5 Sequence number: 1 Tue May 18 13:22:06 2010 Error: 260132755 Host: orp Process: orp_subsys File: Ifb.cxx Line: 953 Running: System Reset Tue May 18 13:22:06 2010 Host : Das Ermes # : 260132755 Exception Class : Abort Severity : Secondary File : Ifb.cxx Line# : 953 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Digital Interface Board(s) Detected An Invalid A/D Board Hardwa

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5206402 FRDM - Outer Modules for CT-750 HD systems. See long description for more information. 5206402 FRDM for Outer Modules for CT-750 HD systems This is the detector module for outer slots for Discovery CT750 HD systems. Part #: 5206402 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: VCT HD FIELD REPLACEABLE MODULE KIT - OUTER SLOTS FOR CONVERTER CARD FRU: Yes Status: Orderable Comments: Per HDVCT RSPL, 212008898, 8/12/08.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.