LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Table would not move in or out. Table would not move in or out

Error message

Error 260134500 TCB is not in the READY state See long description for full error Mon Apr 6 14:59:09 2009 Error:260134500 Host: tgp Process: tgp_subsysFile: gtcb_cmd_misc.cxx Line: 100Mon Apr 6 14:59:09 2009Host : Table Sub-System Ermes # : 260134500Exception Class : Secondary Severity : Pri/SoftFile : gtcb_cmd_misc.cxx Line# : 100Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0Command rejected: TCB is not in the READY stateCommand level is: Initializing Controller.

Error 260134501: Scan Abort GTCB has detected an error. The GTCB has received an out-of-sequence command. see long description Fri Apr 23 01:15:39 2010 Error: 260134501 Host: tgp Process: tgp subsys File: gtcb cmd invalid.cxx Line: 66 Fri Apr 23 01:15:38 2010 Host : Table Sub-System Ermes # : 260134501 Exception Class : Secondary Severity : Pri/Soft File : gtcb cmd invalid.cxx Line# : 66 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0. Scan Abort -- GTCB Has Detected An Error. The GTCB has received an out-of-sequence command. Command 5005 cannot be accepted when the GTCB is in the Initializing Controller command state

Error: 260134510 FPGA register shows unknown ta

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.