GE Healthcare · CTHiSpeed260118169
Scanner Hardware Stopped Scan.
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118169 (40-0106 ) Rotation phase error See Long Description for error explanation Error: 260118169 (40-0106 ) Rotation phase error Error code: 40-0106H Message/explanation: Rotation phase error The Rotation board has detected that the current in the anode stator does not show the correct phase shift between main and auxiliary. Potential cause: 1. Tube stator winding problem 2. Incorrect wiring (one wire open) 3. Phase shift capacitors inverted or wrong value or not connected 4. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance. If not OK, replace tube. Check wiring from rotation board to tube. Check that phase shift capacitors are not swapped, check connection Check that phase shift capacitors are not in short-circuit Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2215674 rotor capacitor set used on ProSpeed FII See LD for details 2215674 rotor capacitor set used on ProSpeed FII Part #: 2215674 Part Type: GP CONSUMABLES Part Weight: 2.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: ROTOR CAPACITOR SET 23/23 FRU: Yes Status: Orderable Parts Offered as: Current: 2215674 Harvested: Not Available Exchange: Not Available Comments: GELS - DEFECTIVE PARTS TO BE PUT ON SHELVES FOR ANALYSIS FP99/04,ROTOR CAPACITOR 23/23 FLS - ROTOR CAPACITOR 23/23 U/O YMS PROSPEED LXI,FXI,DXI REPLACES 2187003 JEDI GENERATOR
- Area
- CT