GE Healthcare · CTHiSpeedVCT
HiSpeed Dual, ProSpeed FII Series
Symptom
Customer can’t scan. Customer can’t scan
Applies to
- Models
- HiSpeed, VCT
- Product
- HiSpeed Dual, ProSpeed FII Series HiSpeed Dual, ProSpeed FII Series Product Name: Hispeed Dual ( Linux ) CT/Be2 A list of types. (a Product/hardware table) This console has an HP8000, HP8200, or HP8400 Computer (not GRE console) An On-site / Remote identification aid . (Example: check_config) HP Host computer A Table of options (included, optional, new introductions, …) HiSpeed Dual for China and Global B71402CA has the following as standard Options 1.5 sec fast scan, Power 200ma, Thichness 1mm, Raw data 5000, Image 100000 A list of Software that has run on this product (Product / Software Compatibility Table) With HP8000/8200 : • OS Version 4.5.15144980•Software Version 2.235165193 (except China)•Software Version 2.235172510 (for China only)•Patch 2.245179238•Patch 2.255197828•Patch 2.275267772 With HP8400 : •OS Version 6.2.95265475•Software Version 3.105270457•Patch 3.305267336•DVD Interchange 6.15270187•Patch 3.40 (See Note 8)5316222•DVD Interchange 7.05316345N/ Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2200197 P9230BE OPT CABLE or OPT CABLE U/O CT HISPEED-YMS GANTRY IF NO STOCK PLEASE USE 2200197U See Long description for details Part #: 2200197 Part Type: GP CONSUMABLES Part Weight: 0.91 KGM Repairable: No Returnable: No Hazardous Material: N Description: P9230BE OPT CABLE FRU: Yes Status: Orderable Parts Offered as: Current : 2200197 Comments: FLS - OPT CABLE U/O CT HISPEED-YMS GANTRY M3 FW20 '98 MS1101 3/98 GELS - 03/09/09 IF NO STOCK PLEASE USE 2200197U NO PDR BOURGFL 9733,OPT CABLE
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required