GE Healthcare · CTLightSpeed182408
LightSpeed 4.X - GRE
Symptom
Table will not move. Table will not move
Error message
Error: 182408 Velocity tracking error. Probable Problem could be 180V Power is LOW. See Long Description for complete error Error: 182408 Host: ETC Process: Elevation File: CmdMotion.c 1.35 12/23/93 Line: 83 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 11:57:28:685 Log Series: 35 HW/SW error: Velocity tracking error. Actual Velocity 0 (.1 mm/sec) Expected Velocity 400 (.1 mm/sec) Tol 320 (.1 mm/sec) Cur Pos 3276 (.1 mm) Elev Direction: 1 (0 = Up 1 = Down). INFO: Probable Problem could be 180V Power is LOW.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372371 Left Table Top Cover - used on LS 2.x - 5.x tables See LD for details 2372371 HPower Left Table Top Cover 2372371 1.000 Yes COVER TABLE TOP LEFT left...... Part #: 2372371 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER TABLE TOP LEFT FRU: Yes Status: Orderable Comments: FLS - TABLE COVER, TOP LEFT. ADDED PER CT PCN 220864. THIS PART REPLACES P/N 2236720 ONLY ON HPOWER SYSTEMS . KEEP USING OLD P/N FOR ALL OTHER PRODUC TS. MS20544 3/31/03. Additional Left Table Top Cover information for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems. Part #: 2236720 <--Use this part # for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems Part Type: GP CONSUMABLES Part Weight: 16.01 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - LEFT FRU: Yes Status: Orderable Comments: FLS - CAN ALSO ORDER OLD COVER 2149735-2 GPC TABLE MOVE TO CHINA 5/24/0NOW ASIA SOURCED. PER PCN 220864, THIS PART HAS BEEN REPLACED BY P/N 2372371, IN ORDER TO BE USED ON HPOWER SYSTEMS. ALSO SOURCED BY ASIA. MS205444 3/31/03. DO NOT DISCOUNT - PER SHAKUN RIGHT: 2236720-2 ONE USE LIGHTSPEED FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
- Area
- CT