Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260007771 DAS Single Card Communication Error See LD for complete error Error: 260007771 DAS Single Card Communication Error (could be MDAS or GDAS) MDAS: Mon Apr 17 08:16:46 2006 Error: 260007771 Host: orp Process: orp_subsys File: CnvBoardInterface.cc Line: 863 Mon Apr 17 08:16:45 2006 Host : Das Ermes # : 260007771 Exception Class : Soft Severity : Sec/Soft File : CnvBoardInterface.cc Line# : 863 Function : No System Function Reported Scan Type : None/Unknown Scan: 1094/2/0 M-DAS Single Card Communication Error. See Following Error Message for Converter Card List Board:19 Command: State Query Status: Communication timeout - no response. GDAS: Sat Aug 16 14:08:17 2008 Error: 260007771 Host: orp Process: orp_subsys File: CnvBoardInterface.cc Line: 863 Sat Aug 16 14:08:16 2008 Host : Das Ermes # : 260007771 Exception Class : Secondary Severity : Sec/Soft File : CnvBoardInterface.cc Line# : 863 Function : No System Function Reported Scan Type : Scout Scan: 27259/1/1 Converter Board Single Card Communication Error.^C See Following Error Message for Converter Card List Board: 81 Command: State Query Status: Communication timeout - no response.

Error: 260007400 Command 106 to C

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues