Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT26011826050068260118367333281187969

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118260 ( 80-1422 ) Overpress or Blown fuse Error: 260118260 ( 80-1422 )Overpress or Blown fuse Wed Aug 17 17:37:03 2005 Error: 260118260 Host: orp Process: orp_subsys File: gen_exec.c Line: 2161 Running: System Reset Wed Aug 17 17:36:57 2005 Host : Jedi Ermes # : 260118260 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2161 Function : No System Function Reported Scan Type : None/Unknown Scan: 50068/1/0 (80-1422)Overpress or Blown fuse. Z6,Z7= 0h,0h

Error: 260118367 - An unexpected JEDI state change occured - JEDI not ready See long description for full error Thu Jun 12 07:08:56 2008 Error: 260118367 Host: orp Process: orp_subsys File: gen_exec.c Line: 863 Thu Jun 12 07:08:55 2008 Host : On-Board Rotating Processor Ermes # : 260118367 Exception Class : Secondary Severity : Pri/Soft File : gen_exec.c Line# : 863 Function : No System Function Reported Scan Type : Scout Scan: 33328/1/1 An unexpected JEDI state change occured . JEDI not ready -- Tcks: 1187969 Line: 7420

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues