LightSpeed 4.X - GRE
Symptom
"Scanner Hardware Stopped Scan" DURING SMARTVIEW prep WITH Interventional Hand Held Control (IHHC) failed to enable Scanner Hardware Stopped Scan DURING SMARTVIEW prep WITH Interventional Hand Held Control (IHHC) failed to enable See the log description for the full error code Mon Sep 19 10:35:34 2005 Error: 182700 Suite: CT01 Host: ETC Hand Held Control Process: Diag Exec File hc_e xec.c 1.38 No Method Line: 595 Function: Diagnostics OPERATOR INPUT/OUTPUT : Tableside Operator Interface Test Name: Unique ID: 58982 Iteration: 1 Exception Level: Hard Time: 18945 Error Type: Firmware Interventional Hand Held Control (IHHC) failed to enable. Verify IHHC is connected to scanner. If IHHC is not connected to scanner, connect IHHC to scanner. If IHHC is connected to scanner, disconnect IHHC from scanner and reconnect IHHC to scanner. Thu Aug 14 12:26:27 2008 Error: 182701 Host: Process: gr:RECEIVE:firmware File: hc_wdog.c 1.7 2/16/99 Line: 255 Function: No System Function Reported Scan: 25796/3/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 12:26:26:920 Log Series: 418 Interventional Hand Held Control (IHHC) Watchdog Timeout. The IHHC has been disabled. HW/SW Error: Probable hardware, possible software, problem
Error message
Error: 182700 Interventional Hand Held Control (IHHC) failed to enable See the long description for the full error code Mon Sep 19 10:35:34 2005 Error: 182700 Suite: CT01 Host: ETC Hand Held Control Process: Diag Exec File hc_e xec.c 1.38 No Method Line: 595 Function: Diagnostics OPERATOR INPUT/OUTPUT : Tableside Operator Interface Test Name: Unique ID: 58982 Iteration: 1 Exception Level: Hard Time: 18945 Error Type: Firmware Interventional Hand Held Control (IHHC) failed to enable. Verify IHHC is connected to scanner. If IHHC is not connected to scanner, connect IHHC to scanner. If IHHC is connected to scanner, disconnect IHHC from scanner and reconnect IHHC to scanner. Error: 200109124 Received BAD SmartStep Start Status From Firmware See Long Discription for Details Mon Jun 1 13:17:42 2009 Error: 200109124 Hst: lsct Process: scanRx File: uifIpcMgrScanRx.c Line: 3034 Function: Data Acquisition : OC Processing Received BAD SmartStep Start Status From Firmware, status = -1, seq_num = 532. Please check connection for the Hand Held Control
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2199947 CT SONATA HAND HELD CONTROLLER CT SONATA HAND HELD CONTROLLER Part number 2199947 CT SONATA HAND HELD CONTROLLER Part number 2199947
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required