Pular para o conteúdo principal
GE Healthcare · CTBrightSpeed29000903020035290820000182120035290624504850000

BrightSpeed HPower, Velocity or Delight HPower

Symptom

Reconstruction Error detected during boot-up - reconSelftest. Reconstruction Error detected during boot-up - reconSelftest . Pop ping pop up box comes up. Attention: Reconstruction Process has stopped.

Error message

Error: 290009030 Failed to stop image_generation process See long description for full error Mon Nov 19 06:31:41 2007 Error: 290009030 Host: darc Process: recon_control File: IGControl.cpp Line: 591 Failed to stop image_generation process.

Error: 200352908 Error occurred while trying to query recon status. See long description for a full sample error. Thu Feb 14 08:28:09 2008 Error: 200352908 Host: oc0 Process: reconSelftest File: reconSelftest.c Line: 623 Error occurred while trying to query recon status. Status = 200001821

Error: 200352906 Errors starting up the recon sub system. See Long Description for complete error Mon Oct 10 11:36:18 2005 Error: 200352906 Host: wbvct1 Process: reconSelftest File reconSelftest.c Line: 314 Errors starting up the recon sub system. Status = 1237

Error: 245048 The dataacq process appears to be down - error returned is -1 See long description for full error Fri Dec 3 14:55:36 2004 Error: 245048 Host: ct99 Process: scanmgr File: start_finish_request.cxx Line: 282 Function: System Control : Scan Control Scan Type: Not scanning Scan: 50000/1/0 Scan Seq Id: 3 The dataacq process appears to be down - error returned is -1

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues