Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183154 KV inverter disabled See Long Description for error Error 183154 OBC Generator gen_control.c 1.39 210 Function: XRAY GENERATION : Xray Exposure Interlocks Scan: 6825/2/2 Type: Helical Exception Level: Pri/Most Severe Time: 11:03:06:745 Log Series: 1015 Generator not ready for exposure. KV inverter disabled due to hardware errors.

Error: 183163 MA fault detected. Filament inverter disabled. see long description for complete error Thu Dec 17 14:54:03 2009 Error: 183163 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 595 Function: No System Function Reported Scan: 7091/2/1 Type: Helical Exception Level: Pri/Soft Time: 14:54:03:535 Log Series: 855 MA fault detected. Filament inverter disabled.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution