GE Healthcare · CTLightSpeedVCT260134510260134500260112018
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Table does not respond to movement commands. Table does not respond to movement commands
Error message
Error: 260134510 FPGA register shows unknown table type (0x0) See long Description. Host : Table Sub-System Ermes # : 260134510 Exception Class : Secondary Severity : Pri/Soft File : gtcb_table_type.cxx Line# : 79 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 FPGA register shows unknown table type (0x0) Please check table type indicater on GTCN Error 260134500 TCB is not in the READY state See long description for full error Mon Apr 6 14:59:09 2009 Error:260134500 Host: tgp Process: tgp_subsysFile: gtcb_cmd_misc.cxx Line: 100Mon Apr 6 14:59:09 2009Host : Table Sub-System Ermes # : 260134500Exception Class : Secondary Severity : Pri/SoftFile : gtcb_cmd_misc.cxx Line# : 100Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0Command rejected: TCB is not in the READY stateCommand level is: Initializing Controller. Error: 260112018 The UIF configuration file does NOT match the configuration of the current table type (PET or CT). See Long Description for more details Fri Aug 25 11:22:12 2006 Error: 260112018 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 3076 Running Version Management Tool Fri Aug 25 11:22:12 2006 Hos
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required