Pular para o conteúdo principal
GE Healthcare · CTLightSpeed200300842200300846200300831

LightSpeed 4.X - GRE

Symptom

System unable to read Service Proprietary Key with message Service Security Key Non-Proprietary

Error message

Error: 200300842 Unable to open serial port for Security Hard Key. See long description Tue Apr 27 05:20:00 2010 Error: 200300842 Host: ctls Process: sidney File: hardkey.c Line: 84 Unable to open serial port for Security Hard Key.

Error: 200300846 Security Hard Key present but error while closing the serial port See long description Tue Apr 27 05:20:00 2010 Error: 200300846 Host: ctls Process: sidney File: hardkey.c Line: 413 Security Hard Key present but error while closing the serial port.

Error: 200300831 Security Hard Key failure See long description Tue Apr 27 05:20:00 2010 Error: 200300831 Host: ctls Process: sidney File: hardkey.c Line: 83 Security Hard Key failure: Invalid argument. Tue Apr 27 05:20:00 2010 Error: 200300831 Host: ctls Process: sidney File: hardkey.c Line: 412 Security Hard Key failure: Bad file descriptor.

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.