GE Healthcare · CTLightSpeedVCT2100004342002850692000027382100004413863552200002730
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Images fail to display and get suspended in the recon queue
Error message
Error: 210000434 IMAGE ALLOCATION has returned null linkedTuple or null linkedTuple->data See Long Description for complete error Fri Apr 21 07:41:23 2006 Error: 210000434 Host: lightspeed Process: dms File: SaveContext.cxx Line: 184 I MAGE ALLOCATION has returned null linkedTuple or null linkedTuple->data. Error: 200285069 Process examRxDisplay has terminated unexpectedly. Thu Apr 22 13:01:01 2010 Error: 200285069 Host: bidnctscan Process: examRxDisplayMgr File: /bat_pool/work22448/commondisplay/src/cxx Line: 3156 DisplayMgrControl::processHasDisconnected() process avViewer1 has terminated unexpectedly. The manager will attempt to restart this process. Error: 200002738, Creation of hard link to Image file for autoview failed See Long Description for complete error Tue May 23 10:37:48 2006 Error: 200002738 Host: ct01 Process: imagecreate File: ic_imagecreate_req.c Line: 1361 Image : 2928/3/17 Recon Sequence Id : 201 Creation of hard link to Image file for autoview failed Autoview file path : Varies Source file path :Varies Open file name : Varies Directory stat status : 0 File stat status : 0 Errno : OS error : 2 --- No such file or directory Error: 2052 error during execution o
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required