GE Healthcare · CTHiSpeed186436

Scan paused WITH Jedi fails to talk to OGP Error: Event

Symptom

Scan paused WITH Jedi / OGP communication errors. Scan paused WITH Jedi fails to talk to OGP Error: 186436 OGP Event Error.Code : 20-1030-01 Error detected by : OGP OGP did not receive any reply from JEDI in response to Rotor ON/OFF request

Error message

Error: 186436 Code : 20-1030-01 OGP did not receive any reply from JEDI in response to Rotor ON/OFF request Error: 186436 Host: GIMCCT Process: tgp_out File: tgp_errors.c Line: 395 OGP Event Error. Code : 20-1030-01 Error detected by : OGP OGP did not receive any reply from JEDI in response to Rotor ON/OFF request

Applies to

Models
HiSpeed
Product
HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
Component
99185290 FUSE FF 14X51 15A 700VDC C See Long Description for Details. Part #: 99185290 Description: FUSE FF 14X51 15A 700VDC C 50KA ULR Part #: 99185290 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: FUS FF 14X51 15A 700VDC C 50KA ULR FRU: Yes Status: Orderable Comments: Not Available 2409042 (new pn) 2325360-6 (old pn) LVPS 400 (250V) used in JEDI Aux Box of all Xi HiSpeeds and 5.X RT, 60kW 100kW LightSpeeds, Brightspeed 4/8/16 See LD for FEMC info and picture 2409042 (new pn) 2325360-6 (old pn) LVPS 400 (250V) used in JEDI Aux Box of all Xi HiSpeeds and 5.X RT, 60kW 100kW LightSpeeds picture below Note: This Item is listed as a FRU YES for the HP60 but even though the part number is the same, it is listed as a FRU NO for HP100 and RT. Part #: 2325360-6 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: LVPS 400 (250V) BOOT 2.05/APPLI 2.36 FRU: Yes Status: Orderable Comments: FLS - LVPS 400 (250V) BOOT USED ON: GENERATOR, JEDI 100 2.05/APPLI 2.36 VASC 1T ADDED PER SPCN: SUPPLIED BY GEMS INDIA 030903RF141542N1 MS13452 030908 RISK: SITE DOWN FREQUENCY: MEDIUM PER SPCN THIS PART SERVES AS REPLACEMENT FOR 2325360-5, ALL REMAINING STOCK OF -5 IS TO BE UPGRADED TO -6 VERSION. The only difference between pn 2409042 (new pn) and pn 2325360-6 (old pn) is packaging improvment . You can order pn 2325360-6 if no pole stock on pn 2409042 (6/2005 P.Liebau)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.