GE Healthcare · CTHiSpeed1831006500118329618318396082210922
Scanner Hardware Stopped Scan message during axial scan.
Symptom
Scanner Hardware Stopped Scan message during axial scan. Long Description for Feedback Only. Scanner Hardware Stopped Scan message during axial scan
Error message
Error: 183100 Two consecutive kV samples out 10.0 % tolerance Open Long Description to see error example Tue Jun 7 03:35:46 2005 Error: 183100 Suite: GEC2 Host: OBC Process: Generator File: gen_tech.c 1.36 Method: No Method Line: 521 Function: XRAY GENERATION : KV Loop Scan: 65001/11/14 Type: Axial Exception Level: Secondary Time: 03:35:45:575 Log Series: 223 Two consecutive kV samples out 10.0 % tolerance. Selected technic: 140 kV, 56 mA Sample1 = 93.919 kV. Sample2 = 0.000 kV. Error: 183296 Monitoring: (Measured 245.5 mA vs Ref 240 mA) See Long Description for the full error Error: 183296 Suite: CT01 Host: OBC Process: Generator File: gen_tech.c 1.36 Method: No Method Line: 529 Function: No System Function Reported Scan: 65001/8/38 Type: Axial Exception Level: Sec/Soft Time: 03:11:20:495 Log Series: 49 Selected Technic: 100 kV, 240 mA, 0 % Mod, Backup Timer 4324. VarmA: (Index: Start 0, Skip 0, Last 0) Last Cmd 240 mA. Monitoring: (Measured 245.5 mA vs Ref 240 mA) . 5 Total Samples, Tube Spit Ctr 0. (Rotor 0x0000ae04, Gen 0x9c19b5ff, Mon 0x00020000 Error: 183183 kV out of 3 % tol See Long Description for error example Error: 183183 Suite: CT01 Host: OBC Proc: Generator File: ge
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296216P2 PLASTIC FIBER OPTIC CABLE See LD for more info 46-296216P2 PLASTIC FIBER OPTIC CABLE Part #: 46-296216P2 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: PLASTIC FIBER OPTIC CABLE - 113.0 LG FRU: Yes Status: Orderable Comments: FLS - CLASS 1 FRU PDV LENGTH = 121 INCHES
- Area
- CT