Pular para o conteúdo principal
GE Healthcare · CTLightSpeed

LightSpeed 3.X (Ultra, Plus, QX/i) - Octane

Symptom

Ring and streaks appear on images See long description for image Ring and streaks appear on images

Applies to

Models
LightSpeed
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2287134 Mdas or 2287134-4 GDAS Jumper Cable Right or Left, connects to Center Chassis See Long Description for IMPORTANT differences between these two part numbers ! ! 2287134 MDAS or 2287134-4 GDAS Jumper Cable Right or Left side of GDAS that interconnects with the Center chassis NOTE: Check your DAS part number before ordering! 2287134 THIS PART IS FOR MDAS 2358139 ONLY 2287134-4 THIS PART IS FOR GDAS 2358139-2 ONLY Part #: 2287134-4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Harness, GDAS Jumper, ED.2 EMC FRU: Yes Status: Orderable Comments: PART ADDED PER VCT RSPL AND IS EMC2 COMPLETE 12/01/2004 Part #: 2287134 Part Type: GP CONSUMABLES Part Weight: 0.66 LBR Repairable: No Returnable: No Hazardous Material: N Description: MDAS JUMPER HARNESS FRU: Yes Status: Orderable Comments: FLS - MDAS JUMPER HARNESS - RT/LT ADDED VIA PCN 220296. VENDOR CHANGED FROM NORTECH TO SANMINA SCI IN MEXICO PER E-NPI TRANSFER "SANMINA CABLE TRANSFER". MS20544 ON 6/7/02.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues