GE Healthcare · CTLightSpeedVCT26013481210000260134813
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260134812 IMS absolute encoder warning See long description Sun Feb 14 16:22:51 2010 Error: 260134812 Host: tgp Process: tgp_subsys File: gtcb_imc_drv_req.cxx Line: 510 Sun Feb 14 16:22:51 2010 Host : Table Sub-System Ermes # : 260134812 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_drv_req.cxx Line# : 510 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS absolute encoder warning occur. Position is -10000 um. Error: 260134813 IMS absolute encoder communication error occur. See long description Sun Feb 14 16:22:51 2010 Error: 260134813 Host: tgp Process: tgp_subsys File: gtcb_imc_drv_req.cxx Line: 516 Sun Feb 14 16:22:51 2010 Host : Table Sub-System Ermes # : 260134813 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_drv_req.cxx Line# : 516 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS absolute encoder communication error occur. Position is -10000 um.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5122208-2 ABSOLUTE ENCODER FOR IMS GT. See long description. Part #: 5122208-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: ABSOLUTE ENCODER FOR IMS GT FRU: Yes Status: Orderable Comments: source pole/planner code revised per to Global Table transfer
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.