GE Healthcare · CTHiSpeed183425
HiSpeed CTi 6.X with Octane and HSA Gantry
Symptom
Scanner hardware error with 38V Power Supply for the Stepper Motor is too Low. Scanner hardware error with Error: 183425, 38V Power Supply for the Stepper Motor is too Low < 35.0V.
Error message
Error: 183425 38V Power Supply for the Stepper Motor is too Low See LD for details Error: 183425 38V Power Supply for the Stepper Motor is too Low < 35.0V. Thu Oct 21 07:42:05 1999 Error: 183425 Suite: HSOC Host: OBC Process: Control File: Method: No Method Line: 77 Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 1699 Log Series: 2 38V Power Supply for the Stepper Motor is too Low < 35.0V.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA See LD for more info 46-296300G4 and 46-296300G5 EMC COLLIMATOR -used on CTi and compatible to HSA picture 46-296300G4 EMC COLLIMATOR Part #: 46-296300G4 Part Type: GP REPAIRABLES Part Weight: 19.54 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: 860-950117 EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - FE: READ SERVICE NOTE T-1379 5/96 GVR T3202GR MPS INFO: B7999KK CONTAINS G4 COLLIMATOR PLUS S/W. MFG PLANIS TO DEINSTALL THE G3, HAVE FE RETURN, UPGRADE, AND USE INADDITIONAL KITS PER R. KOPP. 10/95 FLS - FE ASSIST MS6588 5/2000 46-296300G4 = GRAPHITE FILTER COLLIMATOR. IF NO STOCK IS AVAILABLE ORDER 46-296300G5. THE G5 COLLIMATOR IS COMPATIBLE ON CTI HSARP AND HSAZ SERIES SYSTEMS. DO YOU STILL WANT TO ORDER THIS PART??? Part #: 46-296300G5 Part Type: GP REPAIRABLES Part Weight: 19.09 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: EMC COLLIMATOR FRU: Yes Status: Orderable Comments: FLS - COST REDUCED EMC COLLIMATOR USED ON FAST RHAPSODE 7/2/97 GWENN 08992 T3202KM 11/19/02 -BUILD OUTSOURCED FRMCT MFG TO ERDA PER GINA DUNDUNM KRAETSCH. MS12464 FLS - FE ASSIST MS6588 5/2000 T3202KM = G5 COLLIMATOR COST REDUCED EMC COLLIMATOR USED ONHSARP, HSA AND CTI SYSTEMS. THE G5 (T3202KM) WILL NOT WORKON HELIOS/LIGHTSPEED SCANNERS. DO YOU STILL WANT TO ORDER THIS PART???
- Area
- CT
Full cause & step-by-step resolution