LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry.

Symptom

Will not scan with "Not enough image space exists. Please remove images". See Long Description for screen capture. Scanner would not allow scouts, axial or helical scanning with message on left screen: Not enough image space exists. Please remove images.

Error message

Error: 210000407 Image space query failed. See Long Description for more details Mon Feb 27 07:19:00 2006 Error: 210000407 Host: csbipct2 Process: dms File: Initialize.cxx Line: 1085 Image space query failed. Error code: -1

Error: 200520015 Updating image space, received a bad status code: See the long description for different status codes Sat Jan 22 18:23:06 2005 Error: 200520015 Host: chr09bc1cti Process: environmentMgr File: ImageSpaceFormMgr.c Line: 117 Updating image space, received a bad status code: 200000416 Reason: Response from SdC timeout you may also see this error with different status codes, such as Fri Jul 28 05:12:48 2006 Error: 200520015 Host: vct1 Process: environmentMgr File: ImageSpaceFormMgr.c Line: 121 Updating image space, received a bad status code: -1 Reason: OS error : -1 --- Unknown error 4294967295 Wed Nov 16 08:23:54 2005 Error: 200520015 Host: gect_qxi Process: environmentMgr File: ImageSpaceFormMgr.c Line: 121 Updating image space, received a bad status code: 200000415 Reason: Invalid data from SdC.

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
08BW17.7 For LightSpeed RT16 & RT16 Xtra See LD for details 08BW17.7 For LightSpeed RT16 & RT16 Xtra sw_hw_string: 08BW17.7.WB_H_G16_G_GTM Released with FMI 22918 Purpose This FMI delivers software release 08BW17.7 to LightSpeed RT16 and LightSpeed Xtra. This software improves the tube warm-up procedure, and delivers safety and quality fixes to improve system reliability. See Product Quality Fixes and Product Safety Fixes section for further details. See Appendix C (In attachment) for improved tube warm-up steps. Product Quality and Safety fixes are the fixes that were included in Service Pack 2.0 for 07MW11.0, 07MW18.4, and 07BW08.4. 5315090 - Class C (Tab# 182) 5315091 - Class M (Tab# 182)
Area
CT