GE Healthcare · CTHiSpeed186218
HiSpeed Dual, ProSpeed FII Series
Symptom
Scan Aborts with JEDI XG Error. Scout Scan Aborts with JEDI XG Error
Error message
Error:186218 Detail error code:50 - 0204H Heater Error: Open circuit (HW detected) See long description for complete error Host: IRIS Proc:tgp_out Error:186218 File:tgp_in_input.c Line:334 XG Error phase is 3 code is 50 Detail error code:50 - 0204H Heater Error: Open circuit (HW detected)
Applies to
- Models
- HiSpeed
- Product
- HiSpeed Dual, ProSpeed FII Series HiSpeed Dual, ProSpeed FII Series Product Name: Hispeed Dual ( Linux ) CT/Be2 A list of types. (a Product/hardware table) This console has an HP8000, HP8200, or HP8400 Computer (not GRE console) An On-site / Remote identification aid . (Example: check_config) HP Host computer A Table of options (included, optional, new introductions, …) HiSpeed Dual for China and Global B71402CA has the following as standard Options 1.5 sec fast scan, Power 200ma, Thichness 1mm, Raw data 5000, Image 100000 A list of Software that has run on this product (Product / Software Compatibility Table) With HP8000/8200 : • OS Version 4.5.15144980•Software Version 2.235165193 (except China)•Software Version 2.235172510 (for China only)•Patch 2.245179238•Patch 2.255197828•Patch 2.275267772 With HP8400 : •OS Version 6.2.95265475•Software Version 3.105270457•Patch 3.305267336•DVD Interchange 6.15270187•Patch 3.40 (See Note 8)5316222•DVD Interchange 7.05316345N/ Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2214604 Filament Board used on Prospeed CT/e See Long Description for part details 2214604 Filament Board used on Prospeed CT/e Part #: 2214604 Part Type: GP CONSUMABLES Part Weight: 0.70 KGM Repairable: No Returnable: No Hazardous Material: N Description: FILAMENT BOARD 1 INVERTER V3.01 FRU: Yes Status: Orderable Comments: FLS - DO NOT DISCOUNT - PER SHAKUN PART IS SET UP WITH A DUEIN RETURN PART AS YOU WOULD A REPAIRBLE TO CLEAR YOUR DUEIN AND GET MATERIAL BACK TO BUC FOR AUTOPSY MS08992 3/15/99 GELS - DEFECTIVE PARTS TO BE PUT ON SHELVES FOR ANALYSIS PDB00/07/27 KANBAN CSS F00,PCB FILAMENT 1 INVERTER (V3.00)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required