LightSpeed 4.X - GRE

Symptom

Fastcal scan aborts. Problem finding a calibration vector or calibration file.

Error message

Error: 200108010 This system has not been fully calibrated for XXX kV. You will not be able to scan at XXX kV until the system has been calibrated for this kV. See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108010 Host: ctxm Process: scanRx File: SIRx.cxx Line: 2380 Function: Data Acquisition : OC Processing This system has not been fully calibrated for 120 kV. You will not be able to scan at 120 kV until the system has been calibrated for this kV.

Error: 200108011 The following calibration vector is not valid: See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108011 Host: ctxm Process: scanRx File: CalStatusInfo.cxx Line: 554 Function: Data Acquisition : OC Processing The following calibration vector is not valid: kV:120 sfov:SFOV_LARGE collimation:0 spotsize:LARGE_SPOT.

Error: 230015036 /usr/g/cal_db/misc/decon/8x125/cal.large_sfov.0.mdk does not exist Tue Feb 20 12:01:41 2007 Error: 230015036 Host: ct01 Process: accs File: cal_db_utils.c Line: 1065 /usr/g/cal_db/misc/decon/8x125/cal.large_sfov.0.mdk does not exist

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.