GE Healthcare · Nuclear MedicineInfinia
Unable to start Xray Scan or QC, getting message failed to start sequence
Symptom
Unable to start Xray Scan or QC, getting message failed to start sequence Unable to start Xray Scan or QC, getting message failed to start sequence.
Error message
CT_ERROR_AIA ,6100,ERROR CT_ERROR_AIA ,6100,ERROR 11:13:16 CTServerComm Got code: (CT_ERROR_AIA,6100,ERROR), Developer message: HkProjectionProvider says: "Chunk Timeout" 11:13:16 WARNING = Warning in PEFApp in Class Message.java:132 - DEVELOPMENT_ERROR_MESSAGE=HkProjectionProvider says: "Chunk Timeout" USER_ERROR_MESSAGE=Error in CT Device. USER_FIX=Try to restart the sequence CODE=(CT_ERROR_AIA,6100,ERROR) SOURCE=com.ge.med.fi.tacq.hwifc.VG.VGCT@2a2397 TIME_CREATED=Wed Mar 11 11:13:16 GMT-05:00 2009 11:13:16 CTServerComm::processMessage Error in CT Device. (CT_ERROR_AIA,6100,ERROR) resolveState returned: 8 11:13:16 SequenceRunner:notifiedScannerError() = seq. state = ACQUISITION 11:13:16 SequenceRunner:: stopOnError Error in CT Device. (CT_ERROR_AIA,6100,ERROR) 11:13:16 Sequence going to notif task owner: Event id:4 from task: Tomo Hawk Feet-1 (com.ge.med.fi.tacq.te.TESequence) 11:13:16 PdaNucAcq notified change sequence was changed 11:13:16 NucProtocol::Sequence had an error, will not autoapply next sequence 11:13:16 SequenceRunner:: stop() 11:13:16 SequenceRunner:: stop(), current task state is: ACQUISITION CT_ERROR_PROJ_DAS_STATUS (Error 6006)
Applies to
- Models
- Infinia
- Product
- Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
- Component
- *Gantry Gantry Gantry 5265864 AIACode for Infinia HE1 and HE4 5265864 AIA Code Board for HE1 and HE4 Part #: 5265864 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: AIACODE BOARD KIT SP FOR HAWKEYE-4 FRU: Yes Status: Orderable
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.