GE Healthcare · CT
Sytec 1600i/1800i SYj Eu
Symptom
Unable to scan with XG errors
Error message
ER-117 XG Fail - contains information on all XG ER117 errors See Long Description ER-117 XG Fail ER–117 ER – 117 : XG Error 00000XYY Error Code X = _ 0: Test Mode 1: Stand–by 2: Preparation Acting 3: Generator Ready 5: Exposure 7: Transition Step to Stand–by ER–117 (continued) ER – 117 : XG Error 00000XYY Error Code YY = _ X01: No DC550V X02: 15V_Safe Error X03: Over Voltage Capacity X11: Rotor Controller Error X12: Rotor Acceleration Error X13: Rotor Feedback Test X14: Rotor Fault Detect Test X16: Low Current Error X18: Unbalance Error X21: Over Filament Current 021: Feedback Test X22: No Filament Current 022: Fault Detect Test X23: Bad Relay Return 023: Small Focus Test X24: No Filament Voltage 024: Large Focus Test X25: Filament Control Error 526: MA measure Error 031: Feedback Test 032: Fault Detector Test 033: Close Loop Test 531: MA Accuracy Error 532: KV Accuracy Error 533: Spit Error 534: Exposure Backup Timer Error 535: Anode Over mA 536: Cathode Over mA 537: Anode Over kV 538: Cathode Over kV 539: Anode Shoot Through 540: Cathode Shoot Through 541: Anode Over Current 542: Cathode Over Current X43: HV ON with Error 544: KV Unbalanced Error X48: Generator Safety Loop Open X
Applies to
- Product
- Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Sytec 1600i/1800i SYj Eu Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3512T X ray tube used on Sytec 1800i / 1600i See lond description Part #: D3512T Part Type: GP TUBES Part Weight: 0.91 KGM Repairable: No Returnable: Yes Hazardous Material: N Description: CT PLUS TUBE UNIT RELOAD FRU: Yes Status: Orderable Parts Offered as: Current: D3512T Harvested: Not Available Exchange: Not Available Comments: FLS - MAXIRAY EQUIVALENT IS D3519T *WARNING: CT PLUS IS A NEW TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FLS - CT PLUS TUBE. FOR SYTEC 1800I, SYTEC 1600I AND CT EMYUSYSTEMS ONLY. "WARNING: PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS NOT COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CT MAX TUBE: D3502T. PLEASE CALL ONLINE CTR IF YOU NEED FURTHERCLARIFICATION." CPD TEAM: NO SYSTEMS IN USA IN 1998. IF FOR DOMESTIC ORDER, FE IS PROBABLY ORDERING INCORRECTLY. (D HAWVER 9/24/98) SOURCE = ASIA (GE-BEL IN INDIA) TUBE DEDICATED FOR SYTEC 1800I, SYTEC 1600I AND CT EMYU SYSTEMS ONLY. PLEASE ENSURE YOU HAVE INSTALLED FMI28505 OR FMI 28506 BEFORE INSTALLING CT-PLUS. THIS TUBE IS *NOT* COMPATIBLE WITH IMAGE MAX, CT MAX I, CT MAX II AND CT MAX 640. FOR THESE SYSTEMS YOU SHOULD PLACE ORDER FOR CTMAX TUBE: D3502T* PLACE ORDER FOR CTMAX TUBE: D3502T*
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required