GE Healthcare · CTBrightSpeed260118170
BrightSpeed HPower, Velocity or Delight HPower
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118170 (40-0107) Rotation Inverter permanent overcurrent See LD for error explanation Code 40 Error code: 40-0107H Message/explanation: Rotation Inverter permanent over current An over current has been detected and 3 restart have been tried unsuccessfully within a single rotation state Potential cause: Tube stator winding problem (shorted) Incorrect wiring (shorted) Rotation board Recommended action/ Troubleshooting guide: Check stator windings impedance. If not OK, replace tube. Check wiring from rotation board to tube. Check that phase shift capacitors are correctly connected and not in short circuit. Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5128609-7 (replaces 5128609) Anode HV CABLE Used on HP60 and BrightSpeed Systems. Introduced April 2006 to correct thermal failure of 2241313-2 P9230TG High Voltage Anode cable See Long Description for details 5128609-7 HV cable - Anode Part #: 5128609-7 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: HV CABLE FRU: Yes Status: Orderable Old FRU Compatible No Comments Added per to ECR2115693 by 305024364 in April 7, 2011 Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5128609-7 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Direct ECO Number ECR2115693 Part #: 5128609 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: HV CABLE Positioning HP60 FRU: Yes Status: Orderable Comments: do not place new order for old p/n(2241313-2), existing old part should be used on HiSpeed Zx/i series only.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required