GE Healthcare · CTLightSpeedVCT26010009226010000925050726010009350164

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

"Scan hardware Stopped Scan" with PDU errors "Scan hardware Stopped Scan" with PDU errorss

Error message

Error: 260100092 The PDU Phase Loss Signal indicates one or more phases of the 480 vac is missing. See long description for full error Error: 2601000092 The PDU Phase Loss Signal indicates one or more phases of the 480 vac are missing. Wed May 20 13:54:03 2009 Error: 260100092 Host: tgp Process: tgp_subsys File: scIsrService.c Line: 302 Wed May 20 13:54:03 2009 Host : Table Gantry Processor Ermes # : 260100092 Exception Class : Abort Severity : Secondary File : scIsrService.c Line# : 302 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Axial Scan: 50507/2/4 The PDU Phase Loss Signal indicates one or more phases of the 480 VAC feeding the HVDC Bus is missing or less than the minimum required voltage. Possible causes: PDU fuses F1, F2, F3, or PDU Control Board

Error: 260100093 PDU HVDC Buss Fault Status. The HVDC did not charge correctly in the alotted time Mon Sep 5 13:55:52 2005 Error: 260100093 Host: tgp Process: tgp_subsys File: scIsrService.c Line: 246 Running diagnostic: kV and mA Test: Xray Functional Test Mon Sep 5 13:55:51 2005 Host : Table Gantry Processor Ermes # : 260100093 Exception Class : Abort Severity : Primary File : scIsrService.c Line# : 246 Function : SYS

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
2351495 HVDC Bridge Assembly See long description for details Part #: 2351495Part Type: GP CONSUMABLESPart Weight: 0.88 LBRRepairable: NoReturnable: NoHazardous Material: NDescription: DIODE BRIDGEFRU: YesStatus: Orderable Comments: FLS - DIODE BRIDGE. ADDED PER NGPDU RSPL FROM ASIA. MS20544 ON 1/2/03. 2351494 Capacitor 4600uf / 450 v for NGPDU, Qty 2 required. See long description for details 2351494 Capacitor 4600uf / 450 v for NGPDU, Qty 2 required. Part #: 2351494 Part Type: GP CONSUMABLES Part Weight: 1.32 LBR Repairable: No Returnable: No Hazardous Material: N Description: 4600UF/450V CAPACITOR FRU: Yes Status: Orderable 4600UF/450V CAPACITOR. ADDED PER NGPDU RSPL FROM ASIA. Quantity 2 required and replace BOTH if one fails.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues