Pular para o conteúdo principal
GE Healthcare · CTLightSpeed11236209111000011236209021142267155

LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2

Symptom

Archiving function for the MOD is grayed out and disabled from use. Archive button on the browser does not respond to cursor clicks.

Error message

Error: 9001 Unable to set connection - server NETserver host plsu See LD for complete error Wed Nov 24 11:21:07 2004 Error: 9001 Host: plsu Process: film_composer File: application.c Line: 274 Unable to set connection - server NETserver host plsu. Tue May 17 20:23:24 2005 Error: 9001 Host: rhapsmct1 Process: netserver File: application.c Line: 215 Unable to set connection - server ARSserver host rhapsmct1.

Error: 3005 netserver Can't connect with ct01:AQSserver See LD for other examples of this error Tue Aug 9 13:54:58 2005 Error: 3005 Host: ct01 Process: netserver Can't connect with ct01: AQSserver (for message from ct01:QRS.2754, code: 7008, tag: 1123620911) Tue Aug 9 13:54:59 2005 Error: 3005 Host: ct01 Process: netserver Can't connect with ct01: TESTCLIENT.2737 (for message from ct01:ARSserver, code: 10000, tag: 1123620902) NOTE: This error message contains variable information: AQSserver = server variable Another example: Mon Mar 13 09:34:43 2006 Error: 3005 Host: ct01 Process: netserver File: netproc.c Line: 536 Can't connect with ct01: QRS.1688 (for message from ct01:DBWserver.1671, code: 1760, tag: 1142267155)

Applies to

Models
LightSpeed
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2 This is HP CPU host running LINUX with Pegasus IG. 308L.8_H3.3M4 ~ 4 or 8 slice MDAS. ~ Could be an Ultra, Plus or QXi system. Must run swokinstall -p to verify. ~ See Long description for details . LightSpeed 3.X MDAS4 Gantry and GOC2 Gantry - 2281177-2, DAS - 2272768, Console – 2341104-2, Table - 2276776, PDU - 2269902 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.