Pular para o conteúdo principal
GE Healthcare · Nuclear MedicineInfinia1040111401

Infinia Un-mapped studies queried from the Modality Worklist (MWL) are listed as [UNDEFINED] in the To Do List…

Infinia Un-mapped studies queried from the Modality Worklist (MWL) are listed as [UNDEFINED] in the To Do List

Symptom

Infinia Un-mapped studies queried from the Modality Worklist (MWL) are listed as [UNDEFINED] in the To Do List Infinia Un-mapped studies queried from the Modality Worklist (MWL) are listed as [UNDEFINED] in the To Do List. When an unmapped study is acquired (via the [Acquire Study] button or by double clicking on the study), the Select Study Protocol dialog appears. The following issues might be encountered: Even if the user clicks [Edit Protocol] and selects a protocol from the Protocol name drop-down list, the Select Study Protocol dialog still appears when the study is acquired. Selecting a protocol from the [Favorite] folder for an UNDEFINED study results in an error message:“Failed to open protocol (ERROR_PROTOCOL_ACTION_FAILED, 10401, ERROR)”. The study will not be acquired. Affected systems: Infinia II windows XP M4 version: (2.104.119.*) Reference SN43772

Error message

ERROR_PROTOCOL_ACTION_FAILED, 10401, ERROR Failed to open protocol, load sequence error Example Error: Messages Chain: DEVELOPMENT_ERROR_MESSAGE=Failed to perform load operation on protocol EVOLUTION ONE DAY USER_ERROR_MESSAGE=Failed to open protocol USER_FIX=1) Retry the last operation. 2) In the protocol editor, delete the protocol and recreate it. 3) If this is a factory protocol, restore the protocols from your latest backup. CODE=(ERROR_PROTOCOL_ACTION_FAILED,10401,ERROR) SOURCE=EVOLUTION ONE DAY TIME_CREATED=Fri Dec 19 07:29:40 CST 2008 Caused by: DEVELOPMENT_ERROR_MESSAGE=Failed to load sequence USER_ERROR_MESSAGE=Failed to load sequence USER_FIX=Use the Restore utility to restore this file CODE=(ERROR_SEQUENCE_LOADING,11401,ERROR) SOURCE=com.ge.med.fi.tacq.repository.SysDataAdapter@4eff2c

Applies to

Models
Infinia
Product
Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
Software
Infinia II Hawkeye 4 & GP 2.105.030.* (SP2) Infinia II Hawkeye 4 & GP 2.105.030.* (SP2) See SN43847 : P/N 5389346 Software kit - Infinia II GP & Hawkeye 4 SP2 SW Release 2.105.030.3 See Infinia CIS 5191823-100 Infinia II + Hawkeye 4 Imaging System Software version 2.105.030.0 See SN43877 : P/N5396109 Standalone Patch only - Infinia and Hawkeye4 SP2 Cumulative patch Ver. 2.105.030.5 P/N5395606 Software kit - Infinia and Hawkeye4 SP2 and eManual for spare part 2.105.030.5 See FMI40828 : (Suspended) P/N 5400788 Infinia and HWK4 SP2 2.105.030.0 and Cumulative Patch 2.105.030.6 See ITF 5410176-1EN P/N 5410198 Infinia and Hawkeye 4 SP2 Accumulative patch Ver. 2.105.030.9 See SN43914 ( FMI 40834 ) ITF 5419572-1EN Infinia Hwk4 SP2 Cumulative Patch Installation 2.105.030.10 P/N 5419735 Infinia II GP & Hawkeye 4 SP2 Cumulative Patch Ver. 2.105.030.10 See ITF 5430930-1EN Infinia II GP & Hawkeye 4 SP2 Cumulative Patch 2.105.030.11
Component
*Software Software Software
Area
Nuclear Medicine

Full cause & step-by-step resolution